Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk
Fuji FKC 15K/20K – DP transmitter, 1379 bar | easytherm.sk

Fuji FKC 15K / 20K

Fuji FKC 15K / 20K – differential pressure transmitter for high static pressure

Fuji Electric FKC in its high static pressure version measures differential pressure and flow at line pressures up to 1,379 bar (20,000 psi). It is designed for demanding oil and gas applications.

  • Static pressure: 575 to 1,035 bar (15K) or 1,379 bar (20K).
  • Ranges: 32 to 3,000 kPa (320 mbar to 30 bar).
  • Accuracy: ±0.1% of set span.
  • Communication: 4–20 mA + HART or Modbus RS-485.
  Request an individual quote
Fuji FKC 15K / 20K

Fuji FKC 15K / 20K

Fuji FKC 15K / 20K – differential pressure transmitter for high static pressure

Fuji Electric FKC in its high static pressure version measures differential pressure and flow at line pressures up to 1,379 bar (20,000 psi). It is designed for demanding oil and gas applications.

  • Static pressure: 575 to 1,035 bar (15K) or 1,379 bar (20K).
  • Ranges: 32 to 3,000 kPa (320 mbar to 30 bar).
  • Accuracy: ±0.1% of set span.
  • Communication: 4–20 mA + HART or Modbus RS-485.

I accept privacy policy  

 

Differential pressure transmitter for extreme static pressure: Fuji Electric FKC 15K / 20K

The Fuji Electric FKC in its high static pressure version measures differential pressure and flow at line pressures up to 1,379 bar (20,000 psi). It builds on more than 15 years of Fuji Electric experience in supplying transmitters to the oil and gas industry and is designed for both topside and subsea applications.

The micro-capacitive silicon sensor is mounted "floating" in the neck of the measuring cell and surrounded by transfer oil. This design greatly reduces the influence of static pressure on the measurement. The fully welded, gasket-free construction and SS 660 bolting ensure mechanical strength certified according to PED category IV, module H1.


Key benefits and features

  • Extreme static pressure: 15K version up to 575, 690, 860 or 1,035 bar; 20K version up to 1,379 bar.
  • Accurate measurement of small differences: differential pressure from 130 mbar even at maximum static pressure.
  • Floating silicon sensor: minimal static pressure effect on zero and span.
  • Fully welded design: process covers welded to the measuring cell instead of gaskets.
  • Flow measurement: square root output with configurable low flow cut-off (0 to 20%).
  • Communication: 4–20 mA with HART protocol or Modbus RS-485 digital communication.
  • NACE version: wetted parts and bolting according to NACE.

Technical specifications

Parameter FKC 15K FKC 20K
Max. working (static) pressure 575 / 690 / 860 / 1,035 bar 1,379 bar (20,000 psi)
Test pressure 860 to 1,545 bar (depending on version) 2,069 bar (30,000 psi)
Measuring ranges (max.) 320 mbar / 1.3 / 5 / 30 bar 1.3 / 5 / 30 bar
Accuracy ±0.1% of set span (for spans above 1/10 of max.)
Stability ±0.2% of upper range limit / 3 years
Output signal 4–20 mA DC + HART or Modbus RS-485
Process temperature −10 to +120 °C −5 to +120 °C
Ambient temperature −10 to +85 °C −5 to +85 °C
Diaphragm 316L stainless steel, Hastelloy C276 Hastelloy C276
Other wetted parts 316L, Hastelloy C276, Duplex, Inconel 625 Hastelloy C276, Inconel 625
Process connection 1/4" NPT, 1/2" NPT, autoclave UNF autoclave UNF (9/16", 13/16", 3/8", 7/16")
Electrical connection 1/2" – 14 NPT or M20 × 1.5
Electronics housing 316 stainless steel
Bolting ASTM A453 Grade 660 (SS 660)
Hazardous area (optional) ATEX Ex d / Ex ia, FM
Certification PED category IV, module H1; optionally NACE

Options and accessories

  • LCD display (0–100% or custom scale)
  • surge protection (lightning arrester)
  • ATEX or FM hazardous area versions
  • NACE compliant version
  • diaphragm seals according to API, RTJ or customer design (to prevent hydrate formation in subsea applications)
  • mounting bracket for 2" pipe
  • stainless steel tag plate

Where the FKC 15K / 20K is used

The transmitter is designed for flow measurement of water, oil and gas at extremely high line pressures – on production platforms (topside), in subsea production systems, for water and gas injection into reservoirs and in other high-pressure applications.

Need help choosing the right version, range or connection? Contact our technical team. The standard version is available on the Fuji FKC page.

Industrial communication
HART
Modbus
Display
optional
Pressure type
differential
Measuring range
1 – 10 MPa
100 kPa – 1 MPa
up to 100 kPa
Output signal
4–20 mA
Accuracy
±0,1 %
Diaphragm material
316L stainless steel
Hastelloy C
Power supply
loop powered
Device type
pressure transmitter
Medium
gases
liquids
Process connection
1/2" NPT
1/4" NPT
autoclave UNF
Electrical connection
1/2" NPT
cable gland M20 × 1.5
Approvals
ATEX