Fuji FKA – absolute pressure transmitter (FCX-AIV series)
Fuji Electric FKA accurately measures absolute pressure and converts it into a 4–20 mA output signal with HART communication. It is designed for demanding applications in the process industry.
- High accuracy: ±0.2% of span, optionally ±0.1%.
- Long-term stability: ±0.2% of full scale over 10 years.
- Functional safety: SIL 2 (HFT=0) and SIL 3 (HFT=1) according to IEC 61508 and IEC 61511.
- Communication: HART 7, zero and span adjustment also directly on the device.
Accurate absolute pressure measurement: Fuji Electric FKA transmitter
The Fuji Electric FKA pressure transmitter from the FCX-AIV series accurately measures absolute pressure and converts it into a proportional 4–20 mA output signal. At the heart of the measuring element is a micro-capacitive silicon sensor with a proven track record in the process industry.
Digital signal processing in the electronics unit ensures excellent accuracy and long-term stability. The FCX-AIV series meets safety integrity levels SIL 2 (HFT=0) and SIL 3 (HFT=1) according to IEC 61508 and IEC 61511, making it suitable for safety loops as well.
Key benefits and features of the Fuji FKA
- High accuracy: ±0.2% of set span, optionally ±0.1%.
- Long-term stability: ±0.2% of full scale over 10 years.
- Wide measuring ranges: maximum ranges of 16, 130, 500, 3,000 and 10,000 kPa (abs.), with a turndown of up to 100:1.
- Fast response: 40 ms measuring cycle, adjustable damping from 0.04 to 32 s.
- Resistant materials: diaphragm made of 316L stainless steel, Hastelloy C or gold-plated 316L.
- HART 7 communication: remote configuration and diagnostics.
- Easy setup: zero and span via external screw, local indicator with three push buttons or HART.
- Functional safety: SIL 2 / SIL 3 according to IEC 61508 and IEC 61511.
Technical specifications
| Parameter | Value |
|---|---|
| Measured variable | absolute pressure |
| Maximum measuring ranges | 16 / 130 / 500 / 3,000 / 10,000 kPa abs. |
| Span adjustment range | 1 to 1/100 of maximum range |
| Zero elevation / suppression | −100 to +100% of maximum range |
| Accuracy | ±0.2% of set span (optionally ±0.1%, except 16 and 130 kPa ranges) |
| Stability | ±0.2% of full scale / 10 years |
| Measuring cycle | 40 ms |
| Damping | adjustable 0.04 to 32 s |
| Output signal | 4–20 mA DC (min. 250 Ω load for HART) |
| Communication | HART 7 |
| Power supply | 10.5 to 45 V DC (loop powered) |
| Process temperature | −40 to +85 °C (silicone oil filling) |
| Ambient temperature | −40 to +85 °C (with indicator −20 to +80 °C) |
| Wetted materials | 316L stainless steel, PVDF, Hastelloy C, 316L + gold plating |
| Diaphragm material | 316L stainless steel, Hastelloy C, gold-plated 316L stainless steel |
| Housing | L or T shape, low-copper aluminium alloy with polyester coating, or 316 stainless steel |
| Electrical connection | M20 × 1.5 / 1/2" – 14 NPT / Pg13.5 |
| Process connection | 1/4"-18 NPT, optionally 1/2"-14 NPT with oval flange |
| Protection | IP66 / IP67 |
| Hazardous area (optional) | ATEX / IECEx – intrinsic safety (Ex ia) or flameproof (Ex d) |
| Weight | 3.0 kg (without options) |
| Functional safety | SIL 2 (HFT=0), SIL 3 (HFT=1) according to IEC 61508 / IEC 61511 |
Options and accessories
- 5-digit digital indicator, optionally with local configuration via magnetic buttons
- ATEX / IECEx hazardous area versions
- surge protection (lightning arrester)
- stainless steel housing
- degreasing of wetted parts
- NACE MR0175 / ISO 15156 compliant version
- additional stainless steel identification tag
Where the FKA is used
The FKA transmitter is used to measure absolute pressure and vacuum in the chemical, petrochemical and pharmaceutical industries, in the energy sector, in distillation, drying and vacuum processes, and wherever measurement independent of atmospheric pressure fluctuations is required.
Need help choosing the right range, material or connection? Contact our technical team. Find more pressure transmitters in the Pressure sensors and switches category.
- Industrial communication
- HART
- Display
- optional
- Pressure type
- absolute
vacuum - Measuring range
- 1 – 10 MPa
100 kPa – 1 MPa
up to 100 kPa - Output signal
- 4–20 mA
- Accuracy
- ±0,1 %
±0,2 % - Diaphragm material
- 316L stainless steel
Hastelloy C
gold-plated 316L - Functional safety
- SIL 2
SIL 3 - Power supply
- loop powered
- Protection
- IP66/IP67
- Device type
- pressure transmitter
- Medium
- gases
liquids
steam - Process connection
- 1/2" NPT
1/4" NPT - Electrical connection
- 1/2" NPT
Pg13,5
cable gland M20 × 1.5 - Approvals
- ATEX
IECEx