N2000

1/8 DIN process PID controller

48 × 96 mm controller with universal input and extensive I/O – ramp & soak, cascade and master-slave control, USB and optional RS-485.

  • Thermocouple, Pt100, mA, mV and V input
  • 4 relays, 0/4–20 mA analogue output, SSR pulse output
  • 7 programs with 7 segments, 4 alarms, AUTO/MAN
  • Remote setpoint, 24 V DC transmitter supply
  Request an individual quote
N2000

N2000

1/8 DIN process PID controller

48 × 96 mm controller with universal input and extensive I/O – ramp & soak, cascade and master-slave control, USB and optional RS-485.

  • Thermocouple, Pt100, mA, mV and V input
  • 4 relays, 0/4–20 mA analogue output, SSR pulse output
  • 7 programs with 7 segments, 4 alarms, AUTO/MAN
  • Remote setpoint, 24 V DC transmitter supply

I accept privacy policy  

 

1/8 DIN process PID controller with extensive inputs and outputs: NOVUS N2000

The NOVUS N2000 is a 1/8 DIN (48 × 96 mm) process controller with an exceptionally rich set of inputs and outputs, designed for industrial and laboratory applications. Even in the basic version it can be used in master-slave or cascade control systems, and for program control it offers 7 programs with 7 segments each, which can be linked. The USB connector is used for configuration and data logging in the lab, while the optional RS-485 (Modbus RTU) bus is used for field data acquisition and connection to SCADA systems.

The universal measuring input accepts all common thermocouples, Pt100, industrial current and voltage signals, including non-linearised temperature transmitters and flow meters. The control output can be voltage pulse, relay or analogue 0/4–20 mA. The controller has two SPDT and two SPST relays, two combined inputs/outputs (digital input, current output for control or retransmission, pulse output for SSR), an auxiliary analogue input for a remote setpoint and a 24 V DC supply for powering a transmitter.

In operation, switching between automatic and manual control, setting the output in manual mode, selecting a program and enabling or disabling control are easily accessible – using the F and MAN keys or the digital inputs. The design allows the fastest possible replacement in the event of a fault: the electronic unit slides out of the housing while the wires remain connected in the terminal block.


Benefits of the NOVUS N2000 controller

  • Universal input: J, K, T, N, R, S, B, E thermocouples, Pt100, mA, mV and V, including linearisation for flow meters.
  • Rich basic equipment: 4 relays, 2 combined inputs/outputs, analogue output and auxiliary input.
  • Master-slave and cascade: remote setpoint and retransmission of PV or SP as 0/4–20 mA.
  • Program control: 7 programs with 7 segments, linking and repetition, hold when the process lags behind.
  • 4 alarms with timers: sensor break and control loop break detection.
  • Manual control: AUTO/MAN switching with a key directly on the front panel.
  • USB and RS-485: USB as standard, optional RS-485 Modbus RTU; free QuickTune and FieldChart-Lite software.
  • Fast service: withdrawable electronics, 24 V DC transmitter supply, IP65 front panel.

Technical specifications

Parameter Value
Front panel format 1/8 DIN, 48 × 96 mm
Depth / installation depth 92 mm / 79 mm
Panel cut-out 45 × 93 mm (+0.5 / −0.0 mm)
Measuring input universal: thermocouples J, K, T, N, R, S, B, E; Pt100 (3-wire); 0–20 mA, 4–20 mA, 0–50 mV, 0–5 V, 0–10 V; 4–20 mA with linearisation for flow transmitters and non-linearised temperature transmitters
Measuring range Pt100: −200 to +850 °C; J: −110 to +950 °C; K: −150 to +1370 °C; T: −160 to +400 °C; N: −270 to +1300 °C; R, S: −50 to +1760 °C; B: +400 to +1800 °C; E: −90 to +730 °C; analogue signals: −1999 to 9999 (scalable)
Accuracy J, K, T thermocouples 0.25 % of span ±1 °C; N, R, S, B, E 0.25 % of span ±3 °C; Pt100 and analogue signals 0.2 % of span
Resolution / sampling rate 15 bits, 10 measurements per second
Input impedance thermocouples, Pt100, 0–50 mV > 10 MΩ; 0–5 V > 1 MΩ; 4–20 mA 15 Ω
Auxiliary analogue input remote setpoint 0–5 V, 0–10 V, 0–20 mA, 4–20 mA
I/O 1, I/O 2 relay, SPDT, max. 240 V AC, 3 A (resistive load); control, alarm or program segment signalling
I/O 3, I/O 4 relay, SPST, max. 240 V AC, 1.5 A (resistive load); control, alarm or program segment signalling
I/O 5 combined: digital input, current output 0–20 / 4–20 mA (max. 550 Ω) for control or retransmission of PV/SP, or voltage pulse output 10 V (max. 20 mA)
I/O 6 combined: digital input or voltage pulse output 5 V (max. 20 mA)
Digital input functions control or program run/stop, auto/manual mode, local/remote setpoint, program hold, program 1 selection
Transmitter power supply 24 V DC ±10 %, max. 25 mA
Control ON/OFF or PID; heating (reverse action) or cooling (direct action); auto/manual mode; soft start 0 to 9999 s; master-slave and cascade control
PID auto-tuning yes
Program control 7 programs with 7 segments each, program linking (LP) and endless repetition; segment 1 to 9999 minutes or seconds; automatic hold when the process lags behind (PTOL)
Alarms up to 4 process alarms (HI, LO, DIFH, DIFL, DIF) + sensor break and loop break (LBD) detection; alarm timers – single pulse, delayed activation or pulse train 1 to 6500 s
Communication USB (configuration, data logging in the lab); optional RS-485, Modbus RTU (field data acquisition, SCADA)
Software QuickTune (configuration, diagnostics) and FieldChart-Lite (data logging) free of charge; FieldChart-64C, SuperView SCADA
Security numeric password with time lock, 8 levels of parameter protection
Power supply 100–240 V AC/DC (±10 %), 50/60 Hz; 24V model: 12–24 V DC / 24 V AC
Consumption max. 9 VA
Operating conditions 5 to 50 °C, up to 80 % relative humidity, max. altitude 2000 m
Protection front panel IP65, terminals IP30
Design withdrawable electronic unit – replacement without disconnecting the wiring
Approvals CE, UL

Model overview

Order code RS-485 Power supply
N2000 – 100–240 V AC/DC
N2000-24V – 12–24 V DC / 24 V AC
N2000-485 yes 100–240 V AC/DC
N2000-485-24V yes 12–24 V DC / 24 V AC

All models have USB. The RS-485 interface can also be added later with the PCB RS485 N2000 plug-in module.


Where the N2000 is used

The N2000 controller is used to control temperature, pressure, flow, level and other process variables in industrial furnaces, dryers, heat exchangers, boiler rooms, chemical and food processes, plastics processing and laboratories – wherever program, cascade or master-slave control is required. For temperature measurement you can use, for example, our easytherm ET10 cable sensor.

Need help choosing the right controller or sensor? Contact our technical team. Find more controllers in the Controllers category.

Format
1/8 DIN
Measuring sensor
0–5 V
0–10 V
0–20 mA
0–50 mV
4–20 mA
Pt100
thermocouple B
thermocouple E
thermocouple J
thermocouple K
thermocouple N
thermocouple R
thermocouple S
thermocouple T
Number of measuring inputs
1
Control output
current signal
pulse (for SSR control)
relay
Alarm
more than 2
Analog retransmission
Yes
Auxiliary analog input for external value
Yes
Digital input
2
Industrial communication
RS-485
USB
Display
Yes
Mounting
Panel cutout
Application
Constant temperature control
Heating + cooling control (reverse + direct action)
On/off control
PID control + autotuning
Program control
Ramp (ramp + soak)
N2000