Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk
Fuji FKE – flange-mounted level transmitter | easytherm.sk

Fuji FKE

Fuji FKE – flange-mounted level transmitter (FCX-AIV series)

Fuji Electric FKE accurately measures liquid level based on hydrostatic pressure and converts it into a 4–20 mA output signal with HART communication. It mounts with a flange directly on the tank, without impulse lines.

  • High accuracy: ±0.165% of span, optionally ±0.1%.
  • Flanges: DN80 / DN100 (PN16, PN40) or ANSI 3" / 4", extended diaphragm up to 200 mm.
  • Durable materials: 316L, Hastelloy C, Monel, tantalum, titanium, zirconium, PFA.
  • Functional safety: SIL 2 (HFT=0) and SIL 3 (HFT=1) according to IEC 61508 and IEC 61511.
  Request an individual quote
Fuji FKE

Fuji FKE

Fuji FKE – flange-mounted level transmitter (FCX-AIV series)

Fuji Electric FKE accurately measures liquid level based on hydrostatic pressure and converts it into a 4–20 mA output signal with HART communication. It mounts with a flange directly on the tank, without impulse lines.

  • High accuracy: ±0.165% of span, optionally ±0.1%.
  • Flanges: DN80 / DN100 (PN16, PN40) or ANSI 3" / 4", extended diaphragm up to 200 mm.
  • Durable materials: 316L, Hastelloy C, Monel, tantalum, titanium, zirconium, PFA.
  • Functional safety: SIL 2 (HFT=0) and SIL 3 (HFT=1) according to IEC 61508 and IEC 61511.

I accept privacy policy  

 

Accurate level measurement directly on the tank: Fuji Electric FKE flange-mounted transmitter

The Fuji Electric FKE level transmitter from the FCX-AIV series accurately measures the level of liquids based on hydrostatic pressure and converts it into a proportional 4–20 mA output signal with HART communication. The transmitter mounts with a flange directly on the tank wall, so the diaphragm is in direct contact with the process without impulse lines. This makes it suitable for viscous, contaminated, crystallising or aggressive liquids.

At the heart of the measuring element is a micro-capacitive silicon sensor which, combined with digital signal processing, provides excellent accuracy and long-term stability. Advanced Floating Cell technology reduces the influence of temperature variations, static pressure and overpressure. The FCX-AIV series meets safety integrity levels SIL 2 (HFT=0) and SIL 3 (HFT=1) according to IEC 61508 and IEC 61511.


Key benefits and features of the Fuji FKE

  • Flange mounting: DN80 and DN100 flanges (PN16, PN40) or ANSI 3" and 4" (Class 150), no impulse lines on the process side.
  • High accuracy: ±0.165% of set span, optionally ±0.1%.
  • Wide measuring ranges: maximum ranges of 6, 32, 130, 500 and 3,000 kPa (approx. 0.6 to 300 m water column), adjustable with a turndown of up to 100:1.
  • Durable diaphragm materials: 316L stainless steel, Hastelloy C, Monel, tantalum, titanium, zirconium, 316L with PFA lining or gold coating.
  • Extended diaphragm: optionally 50 to 200 mm for tanks with thick or insulated walls.
  • Process temperature: up to +150 °C with silicone oil.
  • Output linearization: up to 14 points, e.g. for volume measurement in horizontal or irregular tanks.
  • Long-term stability: ±0.2% of upper range limit over 10 years.
  • HART 7 communication: remote configuration and diagnostics, burnout current according to NAMUR NE43.
  • Functional safety: SIL 2 / SIL 3 according to IEC 61508 and IEC 61511.

Technical specifications

Parameter Value
Measured variable liquid level (hydrostatic pressure), density, interface
Maximum measuring ranges 6 / 32 / 130 / 500 / 3,000 kPa
Minimum adjustable spans 0.1 / 0.32 / 1.3 / 5 / 30 kPa (depending on model)
Zero elevation / suppression −100 to +100% of upper range limit
Static pressure up to flange rating
Accuracy ±0.165% of set span (optionally ±0.1%), for spans greater than 1/10 of upper range limit
Stability ±0.2% of upper range limit / 10 years
Measuring cycle 40 ms
Damping adjustable 0.04 to 32 s
Output signal 4–20 mA DC (min. 250 Ω load for HART)
Communication HART 7
Power supply 10.5 to 45 V DC (loop powered), 10.5 to 32 V DC with arrester
Process temperature −40 to +150 °C (silicone oil), −20 to +120 °C (fluorinated oil)
Ambient temperature −40 to +85 °C (with indicator −20 to +80 °C)
Process connection (high pressure side) raised face flange: DIN PN40 DN80, DIN PN16 DN100, ANSI Class 150 3" and 4"; in-line or angled mounting
Reference side connection 1/4"-18 NPT, optionally 1/2"-14 NPT with oval flange
Diaphragm and flange face material 316L stainless steel, Hastelloy C, Monel, tantalum, titanium, zirconium, 316L with PFA lining, 316L with gold coating
Diaphragm extension 0, 50, 100, 150 or 200 mm
Mounting flange 316L stainless steel
Filling fluid silicone oil, optionally fluorinated oil
Housing L or T shape, low copper die-cast aluminium with polyester coating, or 316 stainless steel
Electrical connection M20 × 1.5 / 1/2" – 14 NPT / Pg13.5
Protection IP66 / IP67, NEMA 4X
Hazardous area (optional) ATEX / IECEx – intrinsic safety (Ex ia) or flameproof (Ex d)
Weight 10.2 to 19.2 kg (without options)
Functional safety SIL 2 (HFT=0), SIL 3 (HFT=1) according to IEC 61508 / IEC 61511

Options and accessories

  • 5-digit digital indicator, optionally with local configuration via magnetic buttons
  • ATEX / IECEx hazardous area versions
  • surge protection (lightning arrester)
  • stainless steel housing
  • oxygen, chlorine and vacuum service, degreasing of wetted parts
  • NACE MR0175 / ISO 15156 compliant version
  • flange bolts in carbon steel, 316L stainless steel or SS 660
  • additional stainless steel identification tag

Where the FKE is used

The FKE transmitter is used to measure the level, volume and density of liquids in open and closed tanks, vessels, reactors and evaporators. On closed tanks, the reference side is connected to the vapour space of the tank. It is used in the chemical, petrochemical and pharmaceutical industries, power plants, pulp and paper, water supply and wastewater treatment plants.

Need help choosing the right range, flange or material? Contact our technical team. Find more transmitters in the Flow & Level Measurement and Pressure sensors and switches categories.

Industrial communication
HART
Display
optional
Pressure type
differential
Measuring range
1 – 10 MPa
100 kPa – 1 MPa
up to 100 kPa
Output signal
4–20 mA
Accuracy
±0,1 %
±0,165 %
Diaphragm material
316L stainless steel
Hastelloy C
Monel
PFA-lined 316L
gold-plated 316L
tantalum
titanium
zirconium
Functional safety
SIL 2
SIL 3
Power supply
loop powered
Protection
IP66/IP67
Device type
level transmitter
pressure transmitter
Medium
aggressive media
liquids
Process connection
1/2" NPT
1/4" NPT
flange
Electrical connection
1/2" NPT
Pg13,5
cable gland M20 × 1.5
Approvals
ATEX
IECEx
FKE