1/4 DIN process PID controller
96 × 96 mm controller with large display, universal input and extensive I/O – ramp & soak, cascade and master-slave control, USB and optional RS-485.
- Large display with 18 and 13 mm digits
- Thermocouple, Pt100, mA, mV and V input
- 4 relays, 0/4–20 mA analogue output, SSR pulse output
- 7 programs with 7 segments, 4 alarms, remote setpoint
1/4 DIN process PID controller with large display and extensive I/O: NOVUS N3000
The NOVUS N3000 is a 1/4 DIN (96 × 96 mm) process controller with a large display (digit height 18 and 13 mm) and an exceptionally rich set of inputs and outputs, designed for industrial and laboratory applications. Even in the basic version it can be used in master-slave or cascade control systems, and for program control it offers 7 programs with 7 segments each, which can be linked. The USB connector is used for configuration and data logging in the lab, while the optional RS-485 (Modbus RTU) bus is used for field data acquisition and connection to SCADA systems.
The universal measuring input accepts all common thermocouples, Pt100, industrial current and voltage signals, including non-linearised temperature transmitters and flow meters. The control output can be voltage pulse, relay or analogue 0/4–20 mA. The controller has two SPDT and two SPST relays, two combined inputs/outputs (digital input, current output for control or retransmission, pulse output for SSR), an auxiliary analogue input for a remote setpoint and a 24 V DC supply for powering a transmitter.
In operation, switching between automatic and manual control, setting the output in manual mode, selecting a program and enabling or disabling control are easily accessible – using the F function key or the digital inputs. The design allows the fastest possible replacement in the event of a fault: the electronic unit slides out of the housing while the wires remain connected in the terminal block.
Benefits of the NOVUS N3000 controller
- Universal input: J, K, T, N, R, S, B, E thermocouples, Pt100, mA, mV and V, including linearisation for flow meters.
- Rich basic equipment: 4 relays, 2 combined inputs/outputs, analogue output and auxiliary input.
- Master-slave and cascade: remote setpoint and retransmission of PV or SP as 0/4–20 mA.
- Program control: 7 programs with 7 segments, linking and repetition, hold when the process lags behind.
- 4 alarms with timers: sensor break and control loop break detection.
- Large display: 96 × 96 mm format with 18 and 13 mm digits, readable from a distance.
- USB and RS-485: USB as standard, optional RS-485 Modbus RTU; free QuickTune and FieldChart-Lite software.
- Fast service: withdrawable electronics, 24 V DC transmitter supply, IP65 front panel.
Technical specifications
| Parameter | Value |
|---|---|
| Front panel format | 1/4 DIN, 96 × 96 mm |
| Depth / installation depth | 92 mm / 79 mm |
| Panel cut-out | 93 × 93 mm (+0.5 / −0.0 mm) |
| Display | large, digit height 18 and 13 mm |
| Measuring input | universal: thermocouples J, K, T, N, R, S, B, E; Pt100 (3-wire); 0–20 mA, 4–20 mA, 0–50 mV, 0–5 V, 0–10 V; 4–20 mA with linearisation for flow transmitters and non-linearised temperature transmitters |
| Measuring range | Pt100: −200 to +850 °C; J: −110 to +950 °C; K: −150 to +1370 °C; T: −160 to +400 °C; N: −270 to +1300 °C; R, S: −50 to +1760 °C; B: +400 to +1800 °C; E: −90 to +730 °C; analogue signals: −1999 to 9999 (scalable) |
| Accuracy | J, K, T thermocouples 0.25 % of span ±1 °C; N, R, S, B, E 0.25 % of span ±3 °C; Pt100 and analogue signals 0.2 % of span |
| Resolution / sampling rate | 15 bits, 10 measurements per second |
| Input impedance | thermocouples, Pt100, 0–50 mV > 10 MΩ; 0–5 V > 1 MΩ; 4–20 mA 15 Ω |
| Auxiliary analogue input | remote setpoint 0–5 V, 0–10 V, 0–20 mA, 4–20 mA |
| I/O 1, I/O 2 | relay, SPDT, max. 240 V AC, 3 A (resistive load); control, alarm or program segment signalling |
| I/O 3, I/O 4 | relay, SPST, max. 240 V AC, 1.5 A (resistive load); control, alarm or program segment signalling |
| I/O 5 | combined: digital input, current output 0–20 / 4–20 mA (max. 550 Ω) for control or retransmission of PV/SP, or voltage pulse output 10 V (max. 20 mA) |
| I/O 6 | combined: digital input or voltage pulse output 5 V (max. 20 mA) |
| Digital input functions | control or program run/stop, auto/manual mode, local/remote setpoint, program hold, program 1 selection |
| Transmitter power supply | 24 V DC ±10 %, max. 25 mA |
| Control | ON/OFF or PID; heating (reverse action) or cooling (direct action); auto/manual mode; soft start 0 to 9999 s; master-slave and cascade control |
| PID auto-tuning | yes |
| Program control | 7 programs with 7 segments each, program linking (LP) and endless repetition; segment 1 to 9999 minutes or seconds; automatic hold when the process lags behind (PTOL) |
| Alarms | up to 4 process alarms (HI, LO, DIFH, DIFL, DIF) + sensor break and loop break (LBD) detection; alarm timers – single pulse, delayed activation or pulse train 1 to 6500 s |
| Communication | USB (configuration, data logging in the lab); optional RS-485, Modbus RTU (field data acquisition, SCADA) |
| Software | QuickTune (configuration, diagnostics) and FieldChart-Lite (data logging) free of charge; FieldChart-64C, SuperView SCADA |
| Security | numeric password with time lock, 8 levels of parameter protection |
| Power supply | 100–240 V AC/DC (±10 %), 50/60 Hz; 24V model: 12–24 V DC / 24 V AC |
| Consumption | max. 9 VA |
| Operating conditions | 5 to 50 °C, up to 80 % relative humidity, max. altitude 2000 m |
| Protection | front panel IP65, terminals IP30 |
| Design | withdrawable electronic unit – replacement without disconnecting the wiring |
| Approvals | CE, UL |
Model overview
| Order code | RS-485 | Power supply |
|---|---|---|
| N3000 | – | 100–240 V AC/DC |
| N3000-24V | – | 12–24 V DC / 24 V AC |
| N3000-485 | yes | 100–240 V AC/DC |
| N3000-485-24V | yes | 12–24 V DC / 24 V AC |
All models have USB. The RS-485 interface can also be added later with the PCB RS485 N3000 plug-in module.
Where the N3000 is used
The N3000 controller is used to control temperature, pressure, flow, level and other process variables in industrial furnaces, dryers, heat exchangers, boiler rooms, chemical and food processes, plastics processing and laboratories – wherever program, cascade or master-slave control and a display readable from a greater distance are required. For temperature measurement you can use, for example, our easytherm ET10 cable sensor.
Need help choosing the right controller or sensor? Contact our technical team. Find more controllers in the Controllers category.
- Format
- 1/4 DIN
- Measuring sensor
- 0–5 V
0–10 V
0–20 mA
0–50 mV
4–20 mA
Pt100
thermocouple B
thermocouple E
thermocouple J
thermocouple K
thermocouple N
thermocouple R
thermocouple S
thermocouple T - Number of measuring inputs
- 1
- Control output
- current signal
pulse (for SSR control)
relay - Alarm
- more than 2
- Analog retransmission
- Yes
- Auxiliary analog input for external value
- Yes
- Digital input
- 2
- Industrial communication
- RS-485
USB - Display
- Yes
- Mounting
- Panel cutout
- Application
- Constant temperature control
Heating + cooling control (reverse + direct action)
On/off control
PID control + autotuning
Program control
Ramp (ramp + soak)